Functional impression and jaw registration: a single session procedure for the construction of complete dentures*

2004

The conventional fabrication of complete dentures involves two separate clinical sessions for functional impression making and jaw registration. The presented method combines both procedures in one session. The aim of this study was to survey the three-dimensional tooth positions in complete dentures with reference to the ridges to establish arbitrary guideline values that could be used for the manufacturing of tooth-position analogue plastic rims on functional impression trays. New complete dentures were fabricated by supervised undergraduate students in the conventional manner for 104 edentulous patients. The position of the maxillary teeth was surveyed in the horizontal plane using the S…

AdultMaleDental InstrumentsDental Impression TechniqueComputer sciencemedicine.medical_treatmentDentistryMandibleDental Occlusion Balancedstomatognathic systemMaxillamedicineHumansDental Impression TechniqueMaxillary central incisorDenture DesignGeneral DentistryAgedAged 80 and overVertical dimension of occlusionDenture Completebusiness.industryDental occlusionDental Impression MaterialsVertical DimensionMiddle Agedstomatognathic diseasesDenture DesignMaximum intercuspationJaw Relation RecordDental impression materialFemaleMouth EdentulousDenturesbusinessJournal of Oral Rehabilitation
researchProduct

In vitro evaluation of the ability of three apex locators to determine the working length during retreatment.

2005

The purpose of this in vitro study was to evaluate the accuracy of three apex locators in determining the working length during the retreatment process. Twenty extracted single-rooted human teeth with mature apices were used in this study. The root canal length of each tooth was measured placing a #15 file until the tip was visible at the apical foramen. The direct visual measurement was reduced by 0.5 mm and recorded. The root canals were instrumented and filled to the direct visual measurement using lateral compaction technique. After 7 days the teeth were retreated using three apex locators: ProPex, NovApex, and Root ZX, for determining the retreatment working length. Afterward, comparis…

Analysis of VarianceDental InstrumentsChi-Square Distributionbusiness.industryDentistryRoot canal lengthApex (geometry)Tooth ApexRetreatmentIn vitro studyHumansApical foramenDental Pulp CavitybusinessGeneral DentistryMathematicsJournal of endodontics
researchProduct

Cutting efficiency of heat-treated nickel-titanium single-file systems at different incidence angles.

2020

Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical differenc…

Dental InstrumentsHot Temperatureincidence angle0206 medical engineeringStatistical differencecutting efficiency02 engineering and technology03 medical and health sciencesReciprocating motion0302 clinical medicineNickelStatisticsMaterials TestingGeneral DentistryIncidence (geometry)MathematicsTitaniumheat treatmentIncidenceSignificant difference030206 dentistryEquipment Designreciproc blue020601 biomedical engineeringNickel titaniumHeat treatedreciprocationCalipersRoot Canal PreparationAustralian endodontic journal : the journal of the Australian Society of Endodontology IncReferences
researchProduct

Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types.

2015

Objective The aim of this ex vivo study was to compare implant insertion procedures using piezosurgery and conventional drilling in different qualities of bone. Implant bed preparation time, generated heat, and primary implant stability were analyzed. Material and methods Fresh ex vivo porcine bone block samples (cancellous, mixed, and cortical bone) were obtained. The bone quality was quantified by ultrasound transmission velocity (UTV). Each bone sample received three implants of the same diameter using each of the techniques of piezosurgery and conventional twist drills. Time for preparation was taken and the temperature while performing the osteotomy was measured using infrared spectros…

Dental InstrumentsMaterials scienceSpectrophotometry InfraredSwinemedicine.medical_treatmentDentistryIn Vitro TechniquesOsteotomy03 medical and health sciences0302 clinical medicinemedicineAnimalsPiezosurgery030223 otorhinolaryngologyPiezosurgeryDental ImplantsDrillbusiness.industryDental Implantation Endosseous030206 dentistryDental instrumentsOsteotomyResonance frequency analysismedicine.anatomical_structureTorqueCortical boneImplantOral SurgerybusinessCancellous boneBiomedical engineeringClinical oral implants research
researchProduct

Length of endodontic files measured in digital radiographs with and without noise-suppression filters: an ex-vivo study

2011

The aim of this study is to evaluate if theoretically possible edge shifts induced by noise-suppression filters potentially occur on objects found in digital radiographs. Most manufacturers carry out noise-suppression filtering of their images before they are displayed to the user. It is not usually possible for the user to disrupt the function of the filters. The use of these filters can lead to deletion of small image structures.K-files (ISO size 06, 08, 10 and 15) were placed in the root canals of 6 human teeth located in cadaver jaw segments. File tip positions were measured on original and filtered digital images by three observers. The file position was marked on each filtered image a…

Dental InstrumentsRadiographyDentistryMandibleStandard deviationDigital imageCadaverEndodontic filesCadaverHumansRadiology Nuclear Medicine and imagingComputer visionGeneral DentistryMathematicsNoise suppressionPixelbusiness.industryResearchGeneral MedicineEquipment DesignRadiography Dental DigitalImage enhancementOtorhinolaryngologySubtraction TechniqueArtificial intelligenceDental Pulp CavitybusinessArtifactsFiltrationRoot Canal Preparation
researchProduct

Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization

2010

Aim: The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. Study Design: A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted human mandibular first molars. The procedure was repeated to prepare 2 to 8 canals. The following irrigation solutions were used: group 1, RaCe files with 2.5% NaOCl; group 2, RaCe files with normal saline; group 3, Mtwo files with 2.5% NaOCl; and group 4, Mtwo files with normal saline in the manner desc…

Dental InstrumentsRoot canalDentistryMesial rootNickelClinical and Experimental DentistryMaterials TestingmedicineIrrigation SolutionsHumansStatistical analysisGeneral DentistryPreparation proceduresTitaniumbusiness.industrySterilizationElectrochemical TechniquesEquipment DesignSterilization (microbiology):CIENCIAS MÉDICAS [UNESCO]Electrochemical corrosionCorrosionmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgerybusiness
researchProduct

Shaping ability of nickel-titanium rotary instruments in simulated S-shaped root canals.

2009

Objective The aim of this study was to compare the shaping ability of 4 nickel-titanium rotary techniques and 1 hand technique in simulated S-shaped curved root canals. Study design Seventy-five simulated double-curved resin root canals were divided into 5 groups (n = 15). The canals were compared at 12 different levels and at 3 different times: before preparation and after preparation to master apical 25 and 35. Data were statistically analyzed by performing 2-by-2 comparisons with the Tukey parametric test of variance analysis using a confidence interval of 95%. Results All of the 75 resin blocks presented transportation of the root canals by transforming the apical curvature into a strai…

Dental Stress AnalysisDental InstrumentsFlexibility (anatomy)Hand techniqueRoot (chord)Normal DistributionDentistryCurvatureNickelmedicineHumansTooth RootPliabilityGeneral DentistryParametric statisticsMathematicsTitaniumAnalysis of Variancebusiness.industryStructural engineeringStainless SteelModels Dentalmedicine.anatomical_structureOtorhinolaryngologyNickel titaniumSurgeryEquipment FailureOral SurgeryDental Pulp CavitybusinessRoot Canal PreparationDental AlloysOral surgery, oral medicine, oral pathology, oral radiology, and endodontics
researchProduct

Needle perforation of the bowel in childhood

2004

Accidental ingestion of foreign bodies occurs frequently in childhood. The majority of them are passed spontaneously, and conservative management generally is recommended for foreign bodies in the stomach and duodenum. However, in some cases, operative intervention should be considered to prevent undesirable complications, such as intestinal perforation. Two cases of intestinal perforation owing to accidental ingestion of a needle are reported. J Pediatr Surg

MaleGastrointestinal foreign body intestinal perforationDental Instrumentsmedicine.medical_specialtyConservative managementPerforation (oil well)Diagnosis DifferentialForeign-Body MigrationmedicineCecal DiseasesHumansForeign BodiesAbdomen Acutebusiness.industryStomachdigestive oral and skin physiologyJejunal DiseasesGeneral MedicineAppendicitismedicine.diseaseSurgerymedicine.anatomical_structureIntestinal PerforationChild PreschoolPediatrics Perinatology and Child HealthDuodenumAccidental ingestionFemaleSurgeryForeign bodybusinessJournal of Pediatric Surgery
researchProduct

Influence of Instrument Size on the Accuracy of Different Apex Locators: An In Vitro Study

2008

The aim of this in vitro investigation was to determine the accuracy of 4 different electronic apex locators (EALs) with 3 different instrument sizes. For this study 146 roots were embedded in an agar solution. Electronic measurements were made to the physiologic foramen (apical constriction) with the Elements Apex Locator, Justy II, Raypex 5, and ProPex II and K-type files sizes 08, 10, and 15. Statistical significances were calculated with the sign test (P < .001). Exact measurements to the physiologic foramen were made with the Elements Apex Locator, 36.99%, 39.04%, and 44.93%; Justy II, 38.62%, 32.41%, and 43.41%; Raypex 5, 42.76%, 39.31%, and 39.06%; and ProPex II, 38.62%, 43.45%, and …

OrthodonticsDental InstrumentsAnalytical chemistryApical constrictionEquipment DesignElectronics MedicalApex (geometry)Tooth ApexForamenHumansIn vitro studyGeneral DentistryRoot Canal PreparationMathematicsJournal of Endodontics
researchProduct

Failure of ProTaper rotary Ni-Ti instruments used by undergraduate students

2012

Objective: To evaluate the effect of number of uses, angle and radius of curvature and type of instrument on the fracture of ProTaper rotary instruments when used by undergraduate students. Study Design: Three hundred and seventy-six molars, with a total of 1114 root canals, extracted were instrumented by undergraduate students using ProTaper instruments according to the manufacturer´s recommendations. When fracture occurred, data were collected concerning the number of uses, type of instrument, level of fracture, angle and radius of curvature. ANOVA test were used to determine the influence of type of instrument in the incidence of instrument fracture. Logistic regression model was used to…

OrthodonticsDental materialsbusiness.industryResearchMaterials dentalsDental instruments and apparatusAnova testEstudiants universitarisOdontología:CIENCIAS MÉDICAS [UNESCO]CurvatureOdontologiaCiencias de la saludRadius of curvature (optics)Clinical and Experimental DentistryDentistryUNESCO::CIENCIAS MÉDICASFracture (geology)Aparells i instruments odontològicsMedicineCollege studentsbusinessGeneral Dentistry